CK4-8-15 |
|||
Fundamental |
Item |
Specifications |
|
Welding set data channel |
15 or 31 |
||
Number of squzzing channe |
2 |
||
Number of pulsation |
3 |
||
Welding process step |
4 or 8 |
||
Time control |
Heat 1-3 time |
0~99cycles |
|
Other time |
0(2)~99cycles |
||
Pulsation |
2~99times |
||
Current slope |
0-98cycles for pu or down |
||
Current control |
Welding current |
2.0~50.0KA |
|
Voltage compensation control |
Constant current compensation |
||
Current detector coil |
WMC-451N |
||
Additional |
External |
Heat-on output |
Solid-state circuit (Alternately switched |
Pulsation-on output |
|||
Weld input |
Equipped |
||
Welding step timing output |
One make-contact |
||
Outside squeezing mode input |
Equipped |
||
Squeezing pressure control output |
0.00-999kN (for15ch or 31ch)(option) |
||
No work input |
Equipped |
||
Counter |
Spot counter |
0~99(for 15ch or 31ch) |
|
Work counter |
0~999(for15ch or 31ch) |
||
Total spot counter |
0~99999(for15ch or 31ch) |
||
Step-up counter |
0~9999 (for3SVch) |
||
Monitors |
Memory error Up./low. limit current error Full heat check Cooling water error UP./low. limit firing angle monitor |
SCR short-circuited Current checker Contact checker Welding power discontinuation Fused electrode detect / No work |
|
(Error memory capacity : 10 points) |
|||
Data store |
Data backup |
with flash memory |
|
Enviormental condition |
Operation temperature |
0~45℃ |
|
Storing temperature |
-10 ~ +60℃ |
||
Allowable humidity |
45~85% (without condensation) |
||
Power supply |
Control power |
AC100V + 10% -15% 50/60Hz,30VA |
|
Welding power |
AC220V/440V +10% -20% 50/60Hz,30VA |
||
Dimensions |
Vertical type CK4-8-15 |
W90*H300*D325 |
|
Lateral type CK4-8-15P |
W300*H90*D325 |
||
Weight |
Vertial type / Lateral type |
5Kg |
CE2-6-7 |
|||
Welding Condition Setting |
Item |
Specification |
|
Channel |
7channels |
||
Squeezing channel |
2 channel |
||
Weld step |
2 steps |
||
Sequence step |
6 steps |
||
Time Control |
Weld time |
0~99 cycles |
|
Other times |
0(2)~99cycles |
||
Current Upslope time |
0~29cycles |
||
Current Control |
|||
Weldung current |
2.0-49.9kA (When WMC-451N is used) |
||
Current range (secondary) |
5.0~50.0KA (When WMC-451N is used) |
||
Current response speed |
0.5cycle |
||
Constant voltage control and voltage compensation control can be combination |
|||
Welding detection coil |
WMC-451N (1pce) |
||
Counter |
Total counter |
0-999 |
|
Moniter |
Constant current monitor |
±5% |
|
Full heat |
Detection on voltage compensation control |
||
Over temperature |
Lack of cooling water , duty cycle is over. |
||
Weld source |
Weld source detection |
||
thyristor |
Short citcuit of thyristor detection |
||
Count up |
Stop restaring during count up |
||
External input&output |
Weld interlock output |
Non-contact circuit |
|
Weld input |
Non-voltage contact |
||
Monitor reset input |
Non-voltage contact |
||
Release time output |
1a contact |
||
Monitor error output |
1a contact |
||
Squeezing output |
Same voltage as input voltage of Timer |
||
Usage Enviroment |
Ambient temperature |
0~45℃ |
|
Humidity |
45~85% (No condensation) |
||
Input voltage |
Control input voltage |
AC100V~220V , 50/60Hz |
|
Welding input voltage |
AC200V~220V , 380-415V , 50/60Hz |
||
Dimensions |
Q185 x H300 x D245mm (Not including attachment and terminal blocks) |
||
Weight |
4kg |